Specifications 1)Stable structure

2)good mechanical and temperature.

3)Designed with special grooves to advance blowning machine

Air Blowing Cable             Features and Benefits 2,4,6,8 and 12 fibers options. Stable structure, good mechanical and temperature performance. Designed with special grooves to advance blowing distance. Lightweight and proper stiffness, repeat installation. Designed with no gel, easy stripping and handling. Better costs advantage compared to traditional product. Complete accessories, less manpower, lower installation time. Product Picture:   Standards Unless otherwise specified in this specification, all requirements shall be mainly in accordance with the following standard specifications. Optical Fibre …...  ITU-T G.651,G.652,G.655,G.657                               IEC 60793-2-10,IEC 60793-2-50 Optical Cable ……IEC 60794-1-2,IEC 60794-5   Technical Parameter  Basic Performance

Fibre Count

2 Fibres

4 Fibres

6 Fibres

8 Fibres

12 Fibres

Outer Diameter     (mm)

1.15±0.05

1.15±0.05

1.35±0.05

1.50±0.05

1.65±0.05

Weight             (g/m)

1.0

1.0

1.3

1.8

2.2

Min Bend radius     (mm)

50

50

60

80

80

Temperature

Storage:-30°C~ +60°C   Operation:-20°C~ +60°C   Installation:-5°C~ +50°C

                      Testing parameter Fibre Unit Attenuation

Fibre Type

SM G.652D,G.655,G.657

MM 62.5/125

MM 50/125,OM3

Attenuation

0.38dB/km max @1310nm

0.26dB/km max @1550nm

3.5dB/km max @850nm

1.5dB/km max @1300nm

3.0dB/km max @850nm

1.0dB/km max @1300nm

          Blowing Test

Fibre Count

2 Fibres

4 Fibres

6 Fibres

8 Fibres

12 Fibres

Test equipment

PLUMETTAZ:UM25, ERICSSON:F, CATWAY:FBT-1.1

Standard duct

5.0/3.5 mm

Pressure

7bar / 10bar

Typical blowing distance

500m / 1000 m

500m / 1000m

500m / 1000m

500m / 1000m

500m / 800m

Typical blowing time

10 min / 18 min

10 min / 18 min

12 min / 18 min

13 min / 18 min

15 min / 20 min

                          Mechanical Performance      

Test

Standard

Parameters

Test Results

Tension

IEC 60794-1-2-E1

Load is 1×W

fibre strain ≤0.4% at MAX

Additional attenuation ≤0.05dB

fibre strain ≤0.05% after test

Bend

IEC 60794-1-2-E11A

Diam 40mm×3turns

5 cycles at 20°C

Additional attenuation ≤0.05dB,after test

Crush

IEC 60794-1-2-E3

100 N, 60s

Additional attenuation ≤0.05dB,after test

All optical testing proceeded at 1550 nm

                          Standard delivery lengths   Standard delivery lengths are 1000m, 2000m, 4000m, 6000m with a tolerance of -0.5~+1%.    