Model | S-145-5 | S-145-7.5 | S-145-12 | S-145-24 |
DC output voltage | 5V | 7.5V | 12V | 24V |
Output voltage range(Note:2) | ±2% | ±1% | ±1% | ±1% |
Rated output current | 25A | 18A | 12A | 6A |
Output current range | 0-25A | 0-18A | 0-12A | 0-6A |
Wave and noise(Note:3) | 100mV | 100mV | 100mV | 100mV |
Inlet stability(Note:4) | ±0.5% | ±0.5% | ±0.3% | ±0.2% |
Load stability(Note:5) | ±0.5% | ±4% | ±1% | ±0.2% |
DC output power | 125W | 135W | 144W | 144W |
Efficiency | 78% | 80.50% | 80.50% | 0.84 |
Adjustable range for DC voltage | 4.75~5.5V | 6~8V | 10.8-03.2V | 21~28 V |
Input current | 3.2A/115V1.6A/230V | |||
AC inrush current | Cold-start current 35A/115V 6CW230V | |||
Leakage current | <1mA/240VAC | |||
Overload protection | 125%~165% Type: pulsing hiccup shutdown Reset: quto recovery | |||
Setup, rise . hold uptime | 100ms, 50ms. 20ms | |||
Vibration | 10-500HZ, 2G 10min./1 cycle, Period for 60min. Each axes | |||
Withstand voltage | Input and output internal: 1.5KvAC. Input and enclosure: 1.5Kv.AC. Output and enclosure: 0.5KvAC | |||
Working temperature and humidity | -10°c~+60°c (Refer to output derating curve), 20%~90%RH | |||
Store temperature and humidity | -20°c~85°c, 10%~95% RH | |||
Weight | 0.7Kgs | |||
Safety standards | Meet UL1950 requirment (Not apply for the mark) | |||
EMC standards | Meet FCC PART 15 J Conduction class B |