Dor Yang Precision Instrument (Shanghai) Co., Ltd.

Dor Yang 81Light transmittance meter manual

Basic Information
The first chapter, the overview Through the object of luminous flux and the incident light flux ratio for the light transmittance of the object, expressed as a percentage. Light transmittance instrument is mainly used for measuring all kinds of glass, plastic, film, and visible light transmittance of transparent or translucent material, the instrument according to the principle of optical, manufactured using imported components, its operation is simple, accurate measurement, small volume, convenient to carry, especially for field measurement. The second chapter, the application scope Automotive manufacturing and testing, glass, aerospace and other industries of field measurement. Protective film, PC, acrylic plastic products such as light transmittance measurement. Other transparent or translucent materials transmittance measurements. (note: printing, frosted surface, ivory material measurement is not applicable to the machine) The third chapter, the instrument characteristics 1. measurement speed is quick and easy to operate, good sensitivity, high accuracy of measurement 2.has two test modes: SINGLE test (SINGLE) and continuous (CONT INUE) measurement mode 3. Is equipped with four statistics: the maximum (MAX), the minimum (MIN), average (MEA), the measurement frequency 4.Mass storage, can store 800 measurements 5. connected computers to communicate, read to save or print the storage of data (for bandpass host) 6. boot automatic calibration and manual calibration instrument 7. operation process have a hum labeled (a single measurement mode) 8. big LCD with backlight, low voltage indication 9.manual/automatic shutdown function   The fourth chapter, technical parameters A, measuring range: 0.0-99.9% B, the number of measurement: % beam transmission C, measure the thickest object cannot exceed: 18 mm D, measuring objects in the area of not less than 10 mm * 10 mm E, measuring accuracy: 2% or less F, resolution: 0.1% G, host, shape size: 102 mm * 62 mm * 27 mm H, probe dimensions: Φ 38 mm * 118 mm I, the power supply: three quarters (7) alkaline batteries J, using temperature: 0 ℃ and 40 ℃ K, relative humidity less than 85%   The fifth chapter, the screen display The sixth chapter, instrument usage instructions After the instrument is equipped with batteries, press the "ON/OFF" button boot (please ON the white line when the phone is switched ON the probe can't clip), automatic calibration instrument and calibration after successful beeping sound, LCD screen display ""the state into the instrument; If boot failure automatic calibration, LCD display ""at this time also entered into a state of measurement. Analyte measurement through the probe, please put a clip on the white line in the middle, and then press "OK" button, measuring result display on the LCD screen. Analyte, for example the clip to press the "OK" button on the probe, the LCD panel display content is as follows, The current icon for the current measurement result is 55% light transmittance, frequency measurement for 8 times. Chapter Seventh, instrument calibration 1, the instrument automatically on startup calibration "0" and "99.9", after the boot can also press the "CAL" calibration button. The two points (the calibration when the probe can't clamp things and aim to white line) 2, can also according to the needs of measurement chosen values, such as selecting random distribution standard piece, clip on the probe measurements, if the measured values and standard values are different, can through the "+" or "-" buttons to correct. Chapter eighth, measuring mode conversion The instrument is single measurement mode by default, if you want to automatic measurement mode, please press the "OK" button for 2 seconds, converted to automatic measurement mode. Chapter ninth, statistical functions 1, measurement, LCD display measurement frequency, the lower right corner place measurement times as high as 999 times 2, four numerical statistics, MAX (MAX), minimum (MIN), average (MEA) by pressing the buttons on the "TA", take turns to read data. Chapter tenth, delete instruments to save all the data 1, in the shutdown state, at the same time, press the "-" key and "ON/OFF" key, first let go of ON/OFF "and then" let go "-" button, you can delete all stored in the instrument measurement data. 2, also can through the communication software to delete data, softwaremakes specific operations are as following. (for a host with a communication port) Chapter eleventh, instrument maintenance 1, the instrument temperature: 0 ℃ to 40 ℃, relative humidity of 85% or less, the instrument need not when, should take out battery, regularly clean the probe and the standard. 2, away from strong magnetic field, oil pollution, dust, damp places, to prevent the collision
Supplier Information
Dor Yang Precision Instrument (Shanghai) Co., Ltd.
[ Shanghai China ]
More > Other products from this company
Post Buying Request