Product Description AC three phase output type 1000kw electric generators 4012-46TWG2A , it enjoys high stability,reliability, durability and long life with a wide range of power output. It is widely used in the area of communication, industry, projects, mining, rescuing, military and so on. The series of 400,1100,300,2000, 4000 diesel engines are manufactured by UK-Perkins or its Subordinate factory according to global quality standards. The global service net of Hiersun power can provide y ou with reliable and guaranteed service. you with reliable and guaranteed service.
MODEL | HP1000 |
PRIME POWER (KVA/KW) | 1250/1000 |
STANDBY POWER(KVA/KW) | 1375/1100 |
Rated voltage(V) | 400/230 |
Rated speed(rpm) | 1500 |
Rated frequency(Hz) | 50 |
Power factor | 0.8 |
Ambient temperature(°C) | 40 |
Altitude(m) | 1000 |
Connection type | 3 phase 4 wires |
ENGINE MANUFACTURER | POWERED BY PERKINS ENGINE |
Model | 4012-46TWG2A |
Rated Power(kW) | 1166 |
No. of cylinders & configuration | 12 vee form |
Method of operation | 4-stroke |
Speed regulation | Electric governor |
Starting system | DC 24V Electronic start |
Cooling method | Closed-circuit cooling system |
Total displacement(L) | 45.842 |
Compression ratio | 13.6:1 |
Bore×Stroke(mm) | 160×190 |
100% Load fuel consumption(L/h) | ≤259 |
ALTERNATOR MANUFACTURER | STAMFORDARATHON |
Number of Phase | 3 |
Connection Type | 3Phase and 4Wires |
Number of Bearing | 1 |
Power Factor | 0.8 |
Protection Grade | IP23 |
Terminal | 12 |
Winding/ Pitch | 100% Copper 2/3 Pitch |
Cooling Fan | Cast alloy aluminum |
Exciter Type | Brushless, Self-Exciting |
Insulation Class, Temperature Rise | H/H |
Telephone Influence Factor( TIF) | TIF |
Total Harmonic TGH/THC | <1.5% at no load / <5% at load |
Voltage Regulation, Steady State | ≤±1% |
Sustained Short-Circuit Current | 300%(3 in):10s |
CONTROL SYSTEM | Deepsea 7320 |
AC three phase output type 1000kw electric generators 4012-46TWG2A ( Front view)
AC three phase output type 1000kw electric generators engine collection
With Perkins Diesel Generators 9kva-2000kva all range size up
Genset Model | Power Output (kw/kVA) | Engine Model | Alternator Model | Dimension | Weight |
| Prime | Standby | | | Open Type | Open |
HP7 | 7.2/9 | 7.9/9.9 | 403D-11 | BCI164B | 1100×500×1000 | 400 |
HP10 | 10.4/13 | 11.4/14.3 | 403D-15 | BCI164C | 1150×600×1100 | 450 |
HP16 | 16/20 | 17.6/22 | 404D-22 | BCI184E | 1300×600×1150 | 550 |
HP24 | 24/30 | 36.4/33 | 1103A-33G | BCI184G | 1600×730×1250 | 720 |
HP36 | 36/45 | 39.6/49.5 | 1103A-33TG1 | LSA43.2S25 | 1600×730×1250 | 750 |
HP48 | 48/60 | 52.8/66 | 1103A-33TG2 | LSA43.2M45 | 1650×730×1250 | 780 |
HP64 | 64/80 | 70.1888 | 1104A-44TG2 | LSA43.2L6 | 1750×730×1250 | 850 |
HP80 | 80/100 | 88/110 | 1104C-44TAG2 | LSA44.2VS45 | 1850×750×1250 | 900 |
HP112 | 112.8/141 | 124/155 | 1006TAG | LSA44.2M95 | 2250×820×1450 | 1150 |
HP120 | 120/150 | 132/165 | 1006TAG2 | LSA44.2M95 | 2250×820×1450 | 1150 |
HP144 | 144/180 | 158.4/198 | 1106D-E66TAG4 | LSA46.2M3 | 2400×900×1600 | 1500 |
HP160 | 160/200 | 176/220 | 1306C-E87TAG3 | LSA46.2M5 | 2500×1000×1650 | 1300 |
HP182 | 182.4/228 | 200.6/250.8 | 1306C-E87TAG4 | LSA46.2L6 | 2700×1000×1650 | 1650 |
HP200 | 200/250 | 220/275 | 1306C-E87TAG6 | LSA46.2L6 | 2700×1000×1650 | 1700 |
HP280 | 280/350 | 308/385 | 2206A-E13TAG2 | LSA47.2VS2 | 3100×1150×1800 | 2500 |
HP320 | 320/400 | 352/440 | 2206C-E13TAG3 | LSA47.2S4 | 3200×1150×1800 | 2800 |
HP360 | 360/450 | 396/495 | 2506C-E15TAG1 | LSA47.2S5 | 3350×1150×2150 | 3300 |
HP400 | 400/500 | 440/550 | 2506C-E15TAG2 | LSA47.2M7 | 3350×1150×2150 | 3300 |
HP480 | 480/600 | 528/660 | 2806A-E18TAG1A | LSA47.2L9 | 3350×1550×2250 | 3950 |
HP520 | 520/650 | 572/715 | 2806A-E18TAG2 | LSA49.1S4 | 3400×1510×2250 | 4200 |
HP580 | 580/725 | 638/797.5 | 4006-23TAG2A | LSA49.1M6 | 3900×1700×2150 | 4700 |
HP640 | 640/800 | 704/880 | 4006-23TAG3A | LSA49.1M75 | 3900×1700×2150 | 4700 |
HP728 | 728/910 | 800.8/1001 | 4008-TAG1A | LSA49.1L10 | 4800×1870×2450 | 6500 |
AC three phase output type 1000kw electric generators engine 4012-46TWG2A
With Perkins Diesel Generators Radiator with expansion tank( with original Perkins radiator)
With Perkins Diesel Generators controlled by Deepsea controller
AC three phase output type 1000kw electric generators 4012-46TWG2A with ABB MCB
AC three phase output type 1000kw electric generators 4012-46TWG2A Sound attenuated/canopy type/containerized Model optional
Packaging & Shipping Diesel Generator Packaging and shipping ( apply to ocean shipping)
Our Services We are committed to supply diesel generator powered by genuine Cummins, Perkins, Caterpillar, Daewoo, MTU and the engine power pack for oilfield, crane, pump and other construction field. We keep strengthen the supervision over the production and processing course, to establish and perfect the quality guarantee body, please follow us for more news of this industry. Warranty policy Oneyear or 1000 hours guarantee, whichever comes firstly. Cummins Worldwide Services are in charge of the quality issue. Within the guarantee period, any quality problem about spare parts, please send theoriginal spare parts back to us for getting the fresh ones, except the parts from personal damage as well as the breakables. defective spare parts can be replaced for free charge by post.(not include the wearing & consumable parts) FAQ How to size up a diesel generator ? Generating sets are selected based on the electrical load they are intended to supply, the electrical load's characteristics such as kWe, kva, var, harmonic content, surge currents (e.g., motor starting current) and nonlinear loads. The expected duty (such as emergency, prime or continuous power) as well as environmental conditions (such as altitude, temperature and exhaust emissions regulations) must also be considered. range from 8 to 30 kW (also 8 to 30 kva single phase) for homes, small shops and offices with the larger industrial generators from 8 kW (11 kva) up to 2,000 kW (2,500 kva three phase) used for large office complexes, factories. A 2,000 kW set can be housed in a 40 ft (12 m) ISO container with fuel tank, controls, power distribution equipment and all other equipment needed to operate as a standalone power station or as a standby backup to grid power. These units, referred to as power modules are gensets on large triple axle trailers weighing 85,000 pounds (38,555 kg) or more. A combination of these modules are used for small power stations and these may use from one to 20 units per power section and these sections can be combined to involve hundreds of power modules. In these larger sizes the power module (engine and generator) are brought to site on trailers separately and are connected together with large cables and a control cable to form a complete synchronized power plant. A number of options also exist to tailor specific needs, including control panels for autostart and mains paralleling, acoustic canopies for fixed or mobile applications, ventilation equipment, fuel supply systems, exhaust systems, etc.[1] Diesel generators, sometimes as small as 200 kW (250 kva) are widely used not only for emergency power, but also many have a secondary function of feeding power to utility grids either during peak periods, or periods when there is a shortage of large power generators. Company Information Hiersun Group is a China professional manufacturer of diesel generator set, and we are committed to supply diesel generator powered by genuine Cummins, Perkins, Caterpillar, Daewoo, MTU, the engine power pack for oilfield, crane, pump and other construction field. We keep strengthen the supervision over the production and processing course, to establish and perfect the quality guarantee body, please follow us for more news of this industry.