Basic Information
Specifications 1) weichai diesel genset

2)Low fuel consumption

3)8 hours fuel tank

4)Professional test

5)ISO,CE approval

1.The detailed information of weichai diesel genset Introduced from Steyr -Damimler -Puch Company of Austria,WD615are international advanced environmental-friendly high-speed engine products, whose emmission can meet the standard of Euro II. They have the advantages of small size ,light weight , large power output, low consumption ,advanced emmission targets, low noise and high applicability.   The power of this engine is 86-270KW,and speed is 1500r/min or 1800r/m. With electronic speed governor,it also can be assembled with other kind of generator to make up a generator set of 64-250kw. Different  types of engines with  a speed of 1600r/m or 2000r/m can be available to the customers according to their requirement. Now these engines have become the most ideal power source for the stationary power station, backup power, mid-frequency aero power station and speical power supply.  

Genset model

96GF - 400GF

Type

open/sound   proof/weather proof

Rated voltage  

220/380V,230/400V,240/415V,120/240V

Frequency

50/60HZ

Power factor

0.8

Rated speed

1500/1800rpm

output type

AC three   phase/single phase

Motor

brushless

Frequency

<3%

Frequency at   stable state:

<0.5%

Frequency   deviation at instantaneous state

≤+10%

Frequency   return time

≤3s

Voltage   deviation at stable state

≤±1%

Voltage   deviation at instantaneous state

≤+20%

Voltage   return time

≤4s

Voltage   modulation

≤0.3%

        2.The engine parameters of  weichai diesel genset

Model  

 WD615 61D,WD615 64D,WD615 68D,WD615 46D,WD618 42D.

Cooling   Method

air-cooled

Rotating   speed

1500/1800rpm

Governor   system

electrical   or mechanical governor

Aspiration   mode

natural   aspirated or turbocharged

Starting   method

12/24V   DC electric starting

Stroke

4   stroke

           4.The brushless alternator of  weichai diesel genset Compliance with GB755,BS5000,VDE0530,NEMA MG1-22,IEC-34,CSA C22-100and AS1359 standards.  

Brand

Stamford,marathon, leroy somer.ect                                          

Regulator

AVR   automatic voltage regulating

Excite   type

pret   or shunt

Connecting   type

3PH   star, 3PH-DELTA

Steady   frequency change

0-5%

No   load voltage

95%-105

Steady   voltage

≤±1

Insulation   degree

H   degree

Exclosure   degree

IP23

  5.Standard configuration of weichai diesel genset 1) Starting system: DC alternator is used to start engine 2) Short circuit protection: MCCB air switch 3) Cooling system: combined cooling water tank fitted to meet the requirement of radiation at ambient temperature 40°C 4) Filter system: oil, fuel and air filter 5) Accessories: exhaust elbow, bellow, muffler  HWD series genrator sets choose Weichai Steyr and WP series engine assembled with Stanford ,Marathon or other famous brand Alternators. The power range 120-350Kva as a continuous power supply or sandby power applies to super markets ,mines,buildings, oil fields,hospitals,schools,ports,hotels, etc.    6.Optional type of steyr genset for weichai diesel genset 7.After sale-service of weichai diesel genset   18 moths warranty on spare parts free provide & technical support in machine life   8.Some of our PARTNERS for weichai diesel genset To be the best partner of electric power equipments. Please contact us for more details of weichai diesel genset 9.Warm welcome you to visit our factory for weichai diesel genset User Manual: 1. Operators need to be familiar with the operation of generating sets, operating methods, and all control bodies, manual valves,   stopping body position. 2. In the engine room or near the unit, must hoisting of danger notices warning signs associated personnel:    (1) Units exist electric shocks danger;    (2) Units exist scald danger;    (3)Units exist winding, and collision dangers; 3.To avoid fuel, lubricants, and other fire, engine room No smoking. 4. Engine room or other nearest should maintain an appropriate level of fire service equipment (proposed CO2 fire extinguishers). 5. Grounding the entire unit reliably, and meet the applicable requirements of neutral grounding. 6. Above and around the unit should not be unrelated equipment, obstructions and dangerous goods, should be keeping the floor dry and clean without oil.  7. Units will be run by noise, suggest that the staff wear suitable protective equipment, such as earmuffs vehicles. 8.Before any maintenance, must cut off all power lines, particularly the Dc power supply circuit (remove the battery’s anode and cathode), the warning signs must also note “is maintenance“, and should have another concern, especially in the narrow region maintenance at the same time should be notified stop all of this unit operation. 9. To the reliable operation of unit, the settings of unit voltage, frequency, speed and other related parameters and unit controller set up should not be arbitrarily changed except the specialized operators. 10. Units are valuable equipment, for personal safety, operation stability to light, no illegal operation and drink operation.