Jiangxi Baisheng Gate & Door Automation Co., Ltd.

BaiSheng Mobile Security/ Remote Control Led Barriers: BS-3306

Basic Information
BaiSheng  Mobile Security/ Remote Control Led Barriers: BS-3306   Auto parking barriers   Features A. Fully Aluminium housing  B. Housing with led lights and led flash when running , could see clearly in darkness C, Arms can be made from 2 meters to 6 meters, and up/down time could also be controlled from 2 second to 6 seconds.  D.Manual release key could be used to open the booms when power electricity is cut off. 
E.The barrier will automatically return back when meeting obstacles during the process of lifting and falling
F.Infrared photocell, alarm lamp, loop detectors, Airwave switch, back up batteries( For DC motors)  could be optional for you  G. The barrier could match with straight booms, telescopic booms, folding booms, or single-double fence booms.    Auto parking barriers  Technical data
Rated Voltage of the barrier gate AC 220V (10%) 50Hz/60Hz, 110V (10%) 50Hz/60Hz
Rated Motor power of the barrier gate 90WAC/80W DC
Beam length of the barrier gate <=6m
Opening (Closing) time of the barrier gate  2s, 3s, 4s, 6s
Working temperature of the barrier gate  -20oC-+50oC
Weight (kgs) of the barrier gate 60KGS
Barrier's carton Box dimensions of the barrier gate 1.23x0.43x0.4m
Protection grade of the barrier gate IP55
    Auto parking barriers  Barrier related FAQ
Number Trouble Cause Shooting
1 Motor of Barrier does not work 1,No power supply 1,Check power supply
2,Break fuse 2,Change fuse
3,Motor is damaged 3,Change the motor
2 Barrier can open but can not close 1,Photocell is not connected properly 1,Connect the photocell 
2,Photocell beam is block off 2,Clear out obstacle
3,Photocell is broken 3,Change a new device
3 Barroer can open (close) but can not close (open) 1,Position of limit switch is not correct 1,Adjust position
2,Limit switch is damaged 2,Change limit switch
4 Barrier can not locate accurately 1,Distance of limit switch is too large 1,Adjust position of limit switch
2,Limit switch is wrong 2,Change limit switch
3,Magnetic-stell’s position is wrong 3,Re-adjust the position
5 Release device of Barrier is doesn’t work 1,Operating handle is broken 1,Change the handle
2,Worm gears are jammed 2,Rotate the pinion
6 Push the “OPEN” button but the Barrier gate close Whether “+MOTOR-” wires are connected wrong Connect correctly according to wiring diagram
7 Motor of Barrier can work but boom can not work Compression spring of clutch is dead Change the spring
    We are one of the biggest manufacturer for Gate and Door Automation System in China since 1998!  Welcome customers from all over the world to contact and Visit us!   We are Available at:  Pls contact :  Skype:       vickeychan               Mobile:     +86 13870868175 Tel/Fax:  +86 791 8819 6213    whatsApp:     +86 13870868175