15W~650W | ||||||
• Non-PFC, complete protections •High number of economic type safety with series 3.3V, 5V, 7.5V, 9V, 12V, 15V, 24V, 27V,36V, 48V
| ||||||
S-15W | S-25W | S-35W | S-40W | S-50W | S-60W | |
S-75W | S-100W | S-120W | S-145W | S-150W | S-200W | |
S-201W | S-250W | S-300W | S-350W | S-400W | S-500W | |
S-600W
| S-650W
| |
Features :
• AC input range selectable by switch • Protections:Short circuit/Over load/Over voltage • Cooling by free air convection • 100% full load burn-in test • Fixed switching frequency at 83KHz • 2 years warranty |
Model | S-100-5 | S-100-7.5 | S-100-12 | S-100-15 | S-100-24 | S-100-48 | |
Output | DC Voltage | 5V | 7.5V | 12V | 15V | 24V | 48V |
Rated Current | 20A | 13.6A | 8.5A | 6.7A | 4.5A | 2A | |
Current Range | 0~20A | 0~13.6A | 0~8.5A | 0~6.7A | 0~4.5A | 0~2A | |
Rated Power | 100W | 100W | 100W | 100W | 100W | 100W | |
Ripple & Noise (max.) Note.2 | 100mVp-p | 125mVp-p | 125mVp-p | 125mVp-p | 150mVp-p | 150mVp-p | |
Voltage Adj. Range | 4.5~5.5V | 6.75~8.25V | 10.8~13.2V | 13.5~16.5V | 21.6~26.4V | 43.2~52.8V | |
Voltage Tolerance Note.3 | ±2.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | |
Line Regulation | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |
Load Regulation | ±1.0% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |
Setup,Rise time | 1000ms, 30ms at full load | ||||||
Hold time (Typ.) | 20ms at full load | ||||||
Input | Voltage Range | 88 ~ 132VAC/176 ~ 264VAC selected by jumper or switch 248 ~ 370VDC | |||||
Frequency Range | 47~63HZ | ||||||
Efficiency(Typ.) | 76% | 78% | 80% | 81% | 83% | 84% | |
AC Current(Typ.) | 3.15A/115VAC 1.5A/230VAC | ||||||
Inrush Current (Typ.) | COLD START 20A/115VAC 40A/230VAC | ||||||
Leakage Current | <1mA / 240VAC | ||||||
Protection | Over Load | 105 ~ 150% rated output power | |||||
Protection type : Hiccup mode, recovers automatically after fault condition is removed | |||||||
Over Voltage | 5.75 ~ 6.75V | 8.63~10.13V | 13.8 ~ 16.2V | 17.25 ~ 20.25V | 27.6 ~ 32.4V | 55.2~64.8 | |
Protection type : Hiccup mode, recovers automatically after fault condition is removed | |||||||
Environment | Working Temperature | -10 ~ +60°c (Refer to "Derating Curve" ) | |||||
Working Humidity | 20~90% RH Non-condensing | ||||||
Storage temp.& humidity | -20~+85°C, 10~95%RH | ||||||
Temp. coefficient | ±0.03%/°C (0~50°C) | ||||||
Vibration | 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes | ||||||
Safety & EMC (Note 4.) | Safety Standards | UL1012, UL60950-1, TUV EN60950-1, CCC GB4943 approved | |||||
Withstand Voltage | I/P-O/P:1.5KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC | ||||||
Isolation Resistance | I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC/ 25°c / 70% RH | ||||||
EMC Emission | Compliance to EN55022 (CISPR22) Class B, EN61000-3-2,-3 | ||||||
EMC Immunity | Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, light industry level, criteria A | ||||||
Others | MTBF | 314.9K hrs min. MIL-HDBK-217F (25 °c) | |||||
Dimension | 199*98*38mm (L*W*H) | ||||||
Packing | 0.65Kg; 20pcs/14.2Kg/0.8CUFT | ||||||
Note | 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25°C of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. |