10W~200W | ||||
• 90~264VAC input [90~132VAC for LPL(C)-18, 180~264VAC for LPH(C)-18, 180~305VAC for LPV/C-150]
| ||||
SFS-10W | SFS-20W | SFS-30W | SFS-45W | |
SFS-60W | SFS-80W | SFS-100W | SFS-150W | |
SFS-200W
| |
Features :
• Constant voltage design • Universal AC input / Full range • Fully encapsulated with IP67 level (Note.8) • Fully isolated plastic case • Class Ⅱ power unit, no FG • Class 2 power unit • Pass LPS • Suitable for LED lighting and moving sign applications (Note.7) • 100% full load burn-in test • Low cost, high reliability • 2 years warranty |
Model | SFS-80-5 | SFS-80-12 | SFS-80-15 | SFS-80-24 | SFS-80-36 | SFS-80-48 | |
Output | DC Voltage | 5V | 12V | 15V | 24V | 36V | 48V |
Rated Current | 16A | 6.6A | 5.3A | 3.3A | 2.2A | 1.6A | |
Current Range | 0~16A | 0~6.6A | 0~5.3A | 0~3.3A | 0~2.2A | 0~1.6A | |
Rated Power | 80W | 79W | 79W | 79W | 79W | 76W | |
Ripple & Noise (max.) Note.2 | 80mVp-p | 120mVp-p | 120mVp-p | 150mVp-p | 150mVp-p | 150mVp-p | |
Voltage Tolerance Note.3 | ±8.0% | ±5.0% | ±5.0% | ±5.0% | ±5.0% | ±5.0% | |
Line Regulation | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | |
Load Regulation | ±6.0% | ±2.0% | ±2.0% | ±2.0% | ±2.0% | ±2.0% | |
Setup,Rise time Note. 6 | 500ms, 20ms / 230VAC 500ms, 20ms / 115VAC at full load(for 5~36V) ; 500ms, 30ms / 230VAC 500ms, 30ms / 115VAC at full load(for 48V) | ||||||
Hold time (Typ.) | 50ms/230VAC 16ms/115VAC at full load | ||||||
Input | Voltage Range Note.4 | 90 ~ 264VAC 127 ~ 370VDC | |||||
Frequency Range | 47~63HZ | ||||||
Efficiency(Typ.) | 76% | 83% | 83% | 86% | 86% | 86% | |
AC Current(Typ.) | 1.2A/115VAC 1A/230VAC | ||||||
Inrush Current (max.) | COLD START 60A(twidth=525μs measured at 50% Ipeak) at 230VAC | ||||||
Leakage Current | 0.25mA / 240VAC | ||||||
Protection | Over Load | 110 ~ 150% rated output power | |||||
Protection type : Hiccup mode, recovers automatically after fault condition is removed | |||||||
Over Voltage | 5.75 ~ 6.75V | 13.8 ~ 16.2V | 17.25 ~ 20.25V | 27.6 ~ 32.4V | 41.4~48.6V | 55.2~64.8V | |
Protection type : Shut down o/p voltage, re-power on to recover | |||||||
Environment | Working Temperature | -30 ~ +70°c (Refer to "Derating Curve" ) | |||||
Working Humidity | 20~90% RH Non-condensing | ||||||
Storage temp.& Humidity | -40~+80°C, 10~95%RH | ||||||
Temp. coefficient | ±0.03%/°C (0~50°C) | ||||||
Vibration | 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes | ||||||
Safety & EMC (Note 4.) | Safety Standards | UL879(except for LPV-60-5), UL1310(except for LPV-60-5), CSA C22.2 No. 207-M89(except for LPV-60-5, LPV-60-48), CAN/CSA C22.2 No. 223-M91(except for LPV-60-5,LPV-60-48), IP67 approved ; design refer to TUV EN60950-1 | |||||
Withstand Voltage | I/P-O/P:3KVAC | ||||||
Isolation Resistance | I/P-O/P:>100M Ohms / 500VDC / 25°c/ 70% RH | ||||||
EMC Emission | Compliance to EN55022 (CISPR22) Class B, EN61000-3-2 Class A, EN61000-3-3 | ||||||
EMC Immunity | Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, light industry level, criteria A | ||||||
Others | MTBF | 732Khrs min. MIL-HDBK-217F (25°c) | |||||
Dimension | 170*45*35mm (L*W*H) | ||||||
Packing | 0.85Kg; 30pcs/25.5Kg/0.56CUFT | ||||||
Note | 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25°c of ambient temperature. |