TaiFa natural gas gensets manufacturer with ISO14001 certificate
1. Specification of natural gas genset
Genset model
TFCNG800GF
Prime power
1000KVA
Voltage
400/230V
Frequency
50Hz
Speed
1500rpm
Power Factor
0.8(lagging)
Dimensions(mm) (L×W×H)
5060x2350x2650
Genset Weight(kg)
9300kg
KH-600GF natural gas genset
Data of Technology
Emission standard
mg/m³
EII
Intake Air Temperature
Deg C
<45
Before Air to Air
Deg C
82-87
After Air to Air
Deg C
35-42
Generator Data
Rated power factor
0.8
Operation Continous/KW
800
Full power
KW
2210
Electric Efficiency
%
36.2
Thermal Efficiency
%
87.9
Engine Data
Fire order
1R-1L-3R-3L-2R-2L-5R-4L-8R-8L-6R-6L-7R-7L-4R-5L
Over speed
rpm
2160
Over RPM
rpm
2160
Oil
L
177
Water
L
210
Back pressure
kpa
6.8
Comsumption
Natural gas(based on 36Mj/cube)
m3/kw•h
< 0.3
Oil
g/kWh
< 1.6
Thermal Radiation
water radiator and oil radiator
KW
256
Exhaust pipe(based on 120 degree)
KW
304
Engine
KW
40
Alternator
KW
16
Coolant system
Water temperature
Deg C
95
Oil temperature
Deg C
< 120
Exhaust pipe(based on 120 degree)
KW
760
Exhaust pipe System
Before turbo charger
Deg C
665±15
Ratio of exhaust flow
m³/h
9000
Ratio of Fan
m³/s
21
2. Specification of gas engine
Natural gas engine is lean burn
16NG13-880G 4-Stroke, Spark for combustion
Engine cylinder
v- 16
Bore×Stroke (mm×mm)
159 x 159
Displacement (Liter)
50.3
Compressure Ratio
9.5:1
Adimission
Aspirate/Turbo charger
Coolant
Forced Water Cooling Cycle
Fuel pressure
Low and high
Speed controller
GAC of USA
3. Specification of alternator
Alternator brand
Engga
Alternator model
EG400L-800N
Excitation
Brushless ,Self-exciting, AVR automatic voltage regulating,100% Copper winding wire
Winding pitch
2/3 pitch
Poles
4
Bearing
1
Stator winding
12
Insulation
H
Protection
IP21
Duty type
Continuous
AVR type
WT-2
Base line
Fly wheel
Temperature rise
<125 Degree
Overload (100% load)
110% load 1H
Waveform THD
<5%
Adjustment for Voltage
AVR
Adjustment Ratio for Voltage
±5%
Voltage regulation
±1%
No load voltage waveform
<2%
WaveformTIF
< 50
4. Smartgen Controller
24V starter; IP44 level dustproof; Metal box to protected water; dust port can be long-range; switch is for turn on/off by automatic; output/input can reset; malfunction indicated or stop running by automatic;digial display in-out put by relay
Indicate following information by LED:
engine RPM; operation time; oil pressure; water temperature; bettray; generator phine-Valtage; generator phine-current; generator frenquence; Function of Alam; oil Low pressure; water temperature; malfunction of charger; speed high/low; mal-start; generator stop running; mal-restart; losing speed signal; protect progamm; Volt low or high; Frequence low or high; over current; reverse power