Taizhou Taifa New Energy Technology Co.,Ltd Packaging & Delivery Packaging Detail: wooden case Delivery Detail: within 20 days Specification: 1) Engine: Taifa diesel engine, Water-cooled 2) Alternator: Brushless H class insulation, Self excitation, IP 23 protection, AVR regulator,THF < 5%,low radio interference. 3) 3 phase 4 wires
1.Main technical data of gensets |
1.1 | Model | TF80C |
1.2 | Prime power | 80KW/100KVA |
1.3 | Prime voltage | 230/400V |
1.4 | Speed | 1500 rpm |
1.5 | Weight | 1060kg |
1.6 | Overall dimension | 2200*850*1500 |
2.Main technical data of engine |
Taifa engine, 4 stroke. DC start. |
2.1 | Brand | TAIFA |
2.2 | Model | 6BT5.9-G2 |
2.3 | Prime power | 102KW/127.5KVA |
2.4 | Governor type | Electronic |
2.5 | Configuration | 4 cycle , 4 cylinder in line |
2.6 | Air Intake System | Turbocharged |
2.7 | Bore/Stroke | 102×120 mm |
2.8 | Displacement | 5.9 L |
2.9 | Starting method | Electric |
2.10 | Fuel consumption | 212g/kw.h |
3. Main technical data of alternator |
Alternator is selected the new type brushless alternator designed by US Marathon Electric, which has a unique design, advanced structure, small size, light weight, excellent performance, reliable running and easy-to-use operation. |
3.1 | Brand | ENGGA
|
3.2 | Model | EG225L-80N
|
3.3 | Prime power | 102KW/127.5KVA |
3.4 | Configuration | Brushless , self-exciting |
3.5 | Prime voltage | 230V/400V |
3.6 | Frequency | 50 HZ |
3.7 | Power factor | 0.8(lagging) |
3.8 | Phase/wire | 3 phase 4 wires |
3.9 | Isolation | H |
3)THE SPECIFICATIONS OF THE ALTERNATOR: The world first class alternator, brushless and self-excitation, it be can supply excitation in many cases: · STAMFORD/ MARATHON/ LEROY SOMER/ QIANGHUI · Standard pitch winding can be inhibit currents interruption · Insulation Class: H Protection class: H · Frequency at stable state: ≤±1.0% · Telephones interference: THF < 2%, TIF < 50 4) Control system:
a) Automatic alarm system: the unit has the ocus to-optics alarm
system and arrestor for any situation as the start defeat, the water
is over temperature, the oil pulls down, over speed, over load and
over current
b) Operation display:
i) Unit voltage, tri-phase load current and frequency display
ii) Water temperature, oil pressure display
iii) Fuel level, fuel temperature display
iv) Audible and visual alarm lamps and buzzers 5) Supply standard collocation:
a) Diesel engine with all accessories, 3 filter, electric systems
b) Alternator
c) Steel structure
d) Fan and water tank cooling system
e) Flange connector
f) 12 / 24V starting motor and charge engine
g) Air cleaner, fuel cleaner, oil cleaner
h) On-board control panel
i) MCCB air conservation switch
j) 12 / 24V starting accumulator and Battery line
If you have any enquires regarding the above given then do not hesitate to contact us.